{"product_id":"programmable-timer-relay-module-0-1-s-999-min","title":"Programmable timer relay module 0.1 s - 999 min","description":"\u003cp\u003eProduct introduction:\u003c\/p\u003e\n\u003cp\u003e1. Operating voltage: 6--30V\u003c\/p\u003e\n\u003cp\u003e2. Trigger Signal Source: High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilit system (short circuit can also connect with a ground common)\u003c\/p\u003e\n\u003cp\u003e3. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A\u003c\/p\u003e\n\u003cp\u003e4. Optocoupler Isolation: improve the anti-interference ability, after the parameter setting, it will memory forever\u003c\/p\u003e\n\u003cp\u003eWarning: Relay contact is passive and electricity production; 1 channel has the control function on \/ off\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOperation mode:\u003c\/p\u003e\n\u003cp\u003eP1: After triggered signal, power relay on time OP, then turn off; within the OP period following operation:\u003c\/p\u003e\n\u003cp\u003e1) P1.1: signal being triggered again is not effective\u003c\/p\u003e\n\u003cp\u003e2) P1.2: signal being triggered again, start time again\u003c\/p\u003e\n\u003cp\u003e3) P1.3: signal being triggered again, reset; disconnect relay, stop timing\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eP2: giving the trigger signal, the time after shutdown relay CL power relay OP time; then timing, turn off the relay\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eP3.1: give the trigger signal after the power relay on time OP, CL shutdown time relay; then operating cycle above cycle gaive signal again, shutdown relay stop timing; cycle times (LOP) can be set\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eP3.2: after connecting. no need to trigger signal, power relay on time OP, CL shutdown time relay; then the operating cycle above timea cycle (LOP) can be set\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eQ4: keeping the function of the signal; if there is no trigger signal, the time will be canceled, relay stay connected; when the signal disappears, timing OP turn off the relay; over time, if no signal again, the time is cleared\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eTime interval:\u003c\/p\u003e\n\u003cp\u003e0.1 s (minimum) ~ 999 min (maximum) continuously adjustable\u003c\/p\u003e\n\u003cp\u003ehow to choose the time interval:\u003c\/p\u003e\n\u003cp\u003ein the selection of parameter set interface mode, and press the STOP button to select the time\u003c\/p\u003e\n\u003cp\u003exxx. if the decimal point is in some place, the time interval is s-1 999 s\u003c\/p\u003e\n\u003cp\u003exx. x is decimal place is ten, the time interval is 0.1 s 99.9 s-\u003c\/p\u003e\n\u003cp\u003ex. x. x is the decimal point are all on, the time interval is 1 min-999 min\u003c\/p\u003e\n\u003cp\u003eparameter Introduction: OP power over time, turn off time CL, LOP cycle times (1-999 times, \"---\" is unlimited cycle)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHow to set the parameter:\u003c\/p\u003e\n\u003cp\u003e1. First make sure relay operation mode\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e2. According to the operaiting relay mode, the main interface (power module will flash current operating mode; standard mode P1.1, then come intot main interface); long press SET key two seconds and then looen enter selection interface mode; by pressing UP, DOWN key to choose the mode setting (P1.1 ~ P4)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e3. After selecting the mode, press short SET to set the corresponding parameter, then the parameter you want to set will flash \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e(OP power in time; CL power off time; LOP cycle times, \"---\" is unlimited cycle ); by UP, DOWN to set the parameter value, support long press\u003c\/p\u003e\n\u003cp\u003e(increase or decrease quickly) and press slightly (increase or decrease of 1 unit); after setting the parameter value by short press the STOP key to choose decimal place; choose the time interval (corresponding time interval is 0.1 s-999 min); Short press SET to set the current mode next parameter, the process is the same as above\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e4. After the setting mode parameter, press and hold the SET button then hold the current configuration mode will flash, then go back to the main interface; define success parameter main interface: when the relay does not work, it will show \"000\" (no decimal point); the operating state relay, the screen has a decimal point\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMode Select Interface: press and hold the SET key to enter; after setting, long press the SET button back on main interface\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eExpansion Function Key STOP:\u003c\/p\u003e\n\u003cp\u003eActivate Relay mode:\u003c\/p\u003e\n\u003cp\u003e1. NO: PO in power over time, relay can be connected\u003c\/p\u003e\n\u003cp\u003e2. OFF: relay is not allowed to connect, when in the off state\u003c\/p\u003e\n\u003cp\u003ein short main interface press the STOP key to achieve turn ON and OFF, current state will flash; then back to the main interface \u003c\/p\u003e\n\u003cp\u003e(this function is a function of sudden stop, 1 key to turn off the relay)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSleep Mode:\u003c\/p\u003e\n\u003cp\u003eC-P Sleep mode: within 5 minutes, no operation; nixie tube will close auto display, and a function program well\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe d-Normal Mode: nixie tube show ever\u003c\/p\u003e\n\u003cp\u003eNote: Press and hold STOP button for 2 seconds can achieve change from C-P to O-d; Current state will flash and then return to the main interface\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSize: 6.3*3.8*1.5cm\/2.48\"*1.50\"*0.59\"\u003c\/p\u003e","brand":"XY HOBBY","offers":[{"title":"Default Title","offer_id":56158966022518,"sku":"NH-188","price":5.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0929\/4289\/3430\/files\/123.jpg?v=1756228935","url":"https:\/\/newhobby.eu\/products\/programmable-timer-relay-module-0-1-s-999-min","provider":"NEW HOBBY","version":"1.0","type":"link"}